Call sign monitor

test pins

Microprocessor reset pins

Bottom view

The scan timer is factory preset at approximately 5 se­

conds. This can be adjusted from 3 to 15 seconds.

1. Place the SCAN switch to TO.

2. Turn the SQL control fully counterclockwise to open

the squelch.

3. Press the M.CH switch to select memory mode.
4. Initiate scan by pressing the SC key.
5. Adjust VR1 (X53-1440-10) to the desired delay.

5-6-7. TO (Timer Operated) scan timer

5-6-8. Open channel search step size selection

(TM-3530A/2570A/2550A/2530A only)

Cut the diode D22 to change the open channel search
step size for channel linkage from 1 5 kHz to 20 kHz
(from 20 kHz to 40 kHz with the TM-3530A) steps.

Note:

When the diode (D22) is cut, reset the microprocessor
using the procedure on page 15.

5-6-9. Microphone UP/DWN step size and scan

step size selection (TM-2550E only)

The microphone UP/DWN step size and scan step size

can be changed to 1 2.5 kHz by cutting D12 on the con­
trol unit (X53-1440-10). However, frequency entry by
use of the numeric keypad is still possible in either 5 kHz
or 12.5 kHz steps.

Note:

When the diode (D12) is cut, reset the microprocessor

using the procedure on page 1 5.

5-6-10. Microprocessor reset pins

When the microprocessor reset using the procedure on

page 15 is unable or the lithium battery is replaced, short
these two pins while depressing the PS key.

5-6-11. Call sign monitor test pins

The test pins are short-circuited to monitor the own call
signal when the Call Sign Display option is used. Be

careful of noise interfering with the reception due to this
operation.