Installing the DeviceMaster 500 and the SICK LMS Scanner (Windows): 2000472 Rev. C

3

1-Port Enclosed (99439-8) Installation

pressure on the backside of the tabs at the bottom of both DIN rail clips.

2.

Connect the DeviceMaster 500 port labeled 10/100 Ethernet to the same
Ethernet network segment as the host PC
using a standard Ethernet cable.

Note: Comtrol Technical Support recommends connecting the DeviceMaster

500 to a PC/laptop running Windows during initial configuration.

Do not connect the scanner until the port interface type has been
configured in the NS-Link driver. The default serial port setting is RS-
232.

3.

Apply power to the DeviceMaster 500 using the following steps.

a.

Connect the screw terminal power
connector to the wires on the power
supply as displayed. The power supply
must conform to the specifications for the
DeviceMaster 500.

Observe proper ESD techniques when connecting and disconnecting
the DeviceMaster 500.

b.

Use a small flat head screw to lock the wires into place.

c.

Plug the power terminal connector into the DeviceMaster 500.

Note: Align the power plugs properly. The scalloped side of the screw

terminal power connector should be aligned with the scalloped side
of the power jack on the DeviceMaster 500.

d.

If necessary, connect the appropriate power cable to the power supply.

e.

Connect the power supply to the power source.

4.

Verify the Status LED has completed the boot cycle and network connection for
the DeviceMaster 500 is functioning properly using the table below.

Side View

Press

here

Caution

Power Supply†

Specifications

Output voltage

Current

Power

5-30VDC

100 mA (Min.) @ 24VDC

2.5 W

Any power supply that meets current

consumption, voltage, power, and connector
pinouts requirements can be used.

Earth Gnd

Return

Positive

5-30VDC

+

-

Wire gauge:

AWG 12-22

Caution

LED Descriptions 1-Port Enclosed

100

If the 100 LED is lit, it indicates a working 100 MB Ethernet
connection (100 MB network, only). If the LED is not lit, it
indicates a 10 MB Ethernet connection.

Tx/Rx

Displays transmit and receive activity.

Link/Act

When lit, it indicates a working Ethernet connection. The
LED blinks several times during the boot cycle.