Port custom embedded bulk (99474-9) installation, Building the serial ribbon cable – Comtrol SICK LMS User Manual

Page 4

Advertising
background image

4

Installing the DeviceMaster 500 and the SICK LMS Scanner (Windows): 2000472 Rev. C

1-Port Custom Embedded Bulk (99474-9) Installation

Go to

Software Installation

on Page 9 to complete the installation.

1-Port Custom Embedded Bulk (99474-9) Installation

Use the following procedure to set up the 1-port custom embedded bulk
DeviceMaster 500 and LMS scanner at 500K baud.

If necessary, build the serial ribbon cable.

Mount the DeviceMaster 500 and optionally install light pipes (Page 5).

Attach the network and serial cables (Page 6).

Connect the power and verify installation (Page 7).

Building the Serial
Ribbon Cable

Use the following information to build a DB9 serial ribbon cable to connect to the
DeviceMaster 500 1-Port embedded IDC10 connector (J3).

Status

If the LED is lit, it indicates that the DeviceMaster 500 has
power and it has completed the boot cycle.

Note: The Status LED flashes while booting and it takes

approximately 15 seconds for the Bootloader to
complete the boot cycle.
When the Bootloader
completes the cycle, the LED has a solid, steady light
that blinks approximately every 30 seconds.

LED Descriptions 1-Port Enclosed

J3 Header

RS-232

RS-422

RS-485

1

CD

Not used Not used

2

DSR

Not used Not used

3

RxD

RxD-

Not used

4

RTS

TxD+

TRX+

5

TxD

TxD-

TRX-

6

CTS

RxD+

Not used

7

DTR

Not used Not used

8

RI

Not used Not used

9

GND

Not used Not used

10

Not connected

Pin 1

Pin 6

1 2

9 10

Ribbon Cable

10-Pin
Socket

Pin 5

Pin 9

DB9
Male

J3