Table 5. ports 1 through 16 led descriptions – Comtrol VS1100 Configuration Guide User Manual

Page 18

Advertising
background image

18

Power-On Diagnostics

Installing the Hardware

Note: If using an AUI connection to the server, you can determine

proper polarity by using an AUI to 10Base-T converter box.

Note: The first port LED on the VS1000 blinks while it is waiting for

the server to connect with it. Once the server software connects
with the device, the LEDs display port activity and at regular
intervals perform a quick light pattern “sweeping” sequence,
starting with the first port and moving to the last.

If 1—5 LEDs stay on longer than 6 seconds, this indicates a
hardware fault condition. Cycle the power on the VS1000 (turn
the unit off and on). If the problem persists, contact Comtrol
technical support.

Table 5. Ports 1 Through 16 LED Descriptions

Indicator

Description

Flash

Briefly

All LEDs light briefly during the power-
on sequence and then turn off.

1 LED Lit*

A RAM self-test failure or other
mainboard error.

2 LEDs Lit* Ethernet hardware initialization failure.

3 LEDs Lit* A hardware self-test failure.

4 LEDs Lit* A flash memory configuration error.

* The LEDs light up for a about a minute and then the

hardware resets and the same cycle repeats.

Advertising
This manual is related to the following products: