Diagnostic and ip configurator error messages, The cable is not plugged into port 1, The cable was not connected to the correct ports – Comtrol RocketPort Serial Hub Si 8-Port User Manual

Page 7: Hardware in one of the ports is failing, Connecting devices, Building an ethernet crossover cable, Db9 connector pinouts, Building null-modem cables, Build cables or loopback plug, Building an ethernet crossover cabl

Advertising
background image

Diagnostic and IP Configurator Error Messages

7 of 9

Diagnostic and IP Configurator

Error Messages

This table lists some error messages and possible
solutions.

Connecting Devices

Use the following discussion to connect asynchronous
devices to the RocketPort Serial Hub Si ports.

Note: Make sure that you have configured the ports

using the driver for the correct communications
mode before connecting any devices. The default
mode is RS-232. There is a remote possibility
that connecting a peripheral configured for the
wrong mode could damage the peripheral.

1.

Connect your devices to Ports 1 through 4 or 8
(depending on the model), for each RocketPort
Serial Hub Si using the appropriate cable or you
can build your own cables using the

Building Null-

Modem Cables

or

Building Straight-Through

Cables

discussions.

Note: Use the hardware manufacturer’s installation

documentation if you need help with connector
pinouts or cabling for the peripheral device.

2.

Install or reconfigure the driver using the

Software

Installation

documentation or the driver readme

file.

Building an Ethernet Crossover Cable

If you are connecting from the
10Base-T connector on the
RocketPort Serial Hub Si
directly to the NIC card in the
server, you need a crossover
cable. Use the following
information to build or
purchase a cable.

DB9 Connector Pinouts

Use the following pinout
information for the DB9 serial port
connectors on the RocketPort Serial
Hub Si.

Building Null-Modem Cables

Use the following figure if you need to build a null-
modem cable. A null-modem cable is required to use
the bootable diagnostic, the IP Configurator utility, and
for connecting DTE devices.

Note: You may want to purchase or build a straight-

through cable and purchase a null-modem
adapter.

Error Message

Possible Causes

ERROR
DEV_NO_REPLY

1. The COM port selected in the

utility did not match the
physical COM port on the PC.

2. The cable between Port 1 on

the RocketPort Serial Hub Si
and the PC COM port is
incorrect.

3. The cable is not plugged into

Port 1.

4. The RocketPort Serial Hub Si

power was not turned off and
then on before running the
utility.

5. Port 1 is failing and the utility

can not communicate. The Port
1 LED is also lit to indicate a
hardware failure.

RS-485 ERROR

(Diagnostic)

1. The loopback cable between the

two ports is incorrect.

2. The cable was not connected to

the correct ports.

3. Hardware in one of the ports is

failing.

There were errors
during testing.

A key other than Y was entered
during the LED testing sequence
in the Diagnostic.

Caution

Pin

Connects to

Pin

1

3

2

6

3

1

6

2

Pin

RS-232

RS-422

RS-485

1

CD

Not used Not used

2

RxD

RxD-

Not used

3

TxD

TxD-

TRX-

4

DTR

Not used Not used

5

GND

Not used Not used

6

DSR

Not used Not used

7

RTS

TxD+

TRX+

8

CTS

RxD+

Not used

9

Not used Not used Not used

Pin 1

Pin 6

Receptacle

Pin 1

Pin 1

Pin 5

Pin 6

Pin 9

DB9 Male

RP

S

H

-Si

C

o

nnec

tor

TxD
RxD
RTS
CTS
DSR

GND

DCD
DTR

Signal

RxD
TxD
CTS
RTS
DTR

GND

DCD

DSR

Signal

DB9

2
3
8
7
4

5

1
6

Pins

DB25

3
2

4

7

8
6

Pins

Remot

e and R

P

S

H

-Si

DB9

3
2
7
8
6

5

1
4

Pins

20

5

Pin 9 is not connected.

Fe

m

a

le

C

o

nnec

tors

Null-Modem Cables

Advertising