Building straight-through cables, Building additional loopback plugs, Hardware specifications – Comtrol RocketPort Serial Hub Si 8-Port User Manual

Page 8: Specification

Advertising
background image

Building Straight-Through Cables

8 of 9

Building Straight-Through Cables

Use the following figure if you need to build a straight-
through cable. You can use a straight-through cable to
run the bootable diagnostics for RS-485 mode, or you
can build your own and connect only Pins 3 and 7.
Straight-through cables are also used for DCE devices.

Building Additional Loopback Plugs

Loopback connectors are DB9 female serial port plugs,
with pins wired together as shown, that are used in
conjunction with the diagnostic software to test serial
ports. The RocketPort Serial Hub Si is shipped with a
single loopback plug (RS-232/422).

This information can help you build additional plugs or
replace a missing loopback.

Wire the following pins together
for an RS-232 loopback plug:

Pins 1 to 4 to 6

Pins 2 to 3

Pins 7 to 8

Note: The RS-232 loopback plug

also works for RS-422.

Wire the following pins together
for an RS-422 loopback plug:

Pins 2 to 3

Pins 7 to 8

Hardware

Specifications

This table illustrates environmental conditions.

The following table lists electromagnetic compliance
certifications.

The following table illustrates hardware specifications.

Environmental Conditions

Value

Air temperature:

System on
System off

0 to 40

o

C

-20 to 85

o

C

Altitude

0 to 10,000 feet

Heat output:

4-Port
8-Port

22.0

BTU/Hr

26.9

BTU/Hr

Humidity (non-condensing):

System on
System off

8% to 80%

20% to 80%

RPSH

-Si

C

o

nnect

or

DB9

1
2
3
4
5

8

6
7

Pins

DCD
RxD
TxD or TRX-
DTR
GND

CTS

DSR
RTS or TRX+

Signal

DB9

1
2
3
4
5

8

6
7

Pins

DCD
RxD
TxD or TRX-
DTR
GND

CTS

DSR
RTS or TRX+

Signal

RPS

H

-Si
Connect

or

Pin 9 is not connected.

Fe

m

a

le

Fe
m
a

le

RS-485 Loopback Cable

Note: The RS-485 loopback cable only requires that

Pins 3 and 7 to be connected.

Pin 1

Pin 5

Pin 6

Pin 9

RS-232 Only
(Back View)

Pin 1

Pin 5

Pin 6

Pin 9

RS-422 Only
(Back View)

Mean Time between Failures:

4-Port
8-Port

24.2 years
20.8 years

Electromagnetic

Compliances

Status

Emission:

Canadian EMC requirements

CISPR-22/EN55022

Class A

FCC Part 15 Class A

Yes

Immunity:

EN50082

(801-2

ESD

, 801-3 RF,

and 801-4

FT)

Yes

Safety:

EN60950
UL Listed

Yes

Topic

Hardware

Specifications

Baud rate (maximum)

230.4 Kbps

Current consumption:

4-Port
8-Port

54 mA (at 120 VAC)
66 mA (at 120 VAC)

Dimensions

4-port
8-port

6” x 9” x 1.5”
6” x 9” x 2.4”

Driver Control:

Data bits
Parity
Stop bits

7 or 8

Odd, Even, None

1 or 2

Ethernet host interface

10Base-T (10 Mbps)

Hubs per server

Dependent on OS. See the

software documentation.

Line frequency

50 - 60 Hz

Line voltage

100 - 240 VAC

Number of ports

4 or 8

Power consumption:

4-Port
8-Port

6.4 W
8.0 W

Weight

4-Port
8-Port

1 lb 2 oz
1 lb 4 oz

Environmental Conditions

Value

Advertising
This manual is related to the following products: