Hardware Installation and Specifications

RocketModem IV: 2000468 Rev. A - 11

AT S Registers

AT S Registers

This section lists the basic AT Command Set S registers. The S registers use the
following format: ATSr=n<CR> where “r” is the S register number and “n” is the
value or parameter to set it to. To read the current contents of an S Register, issue
ATSr?<CR> where “r” is the register in question. The modem will then display the
value of the S Register.

Note: Sleep Mode Operation – S24 sets the length of time, in seconds, that the

modem will operate in normal mode with no detected telephone line or DTE
line activity before entering low power sleep mode. The timer is reset upon
any DTE or telephone line activity. If S24 is set to zero, the modem will
never enter the low power sleep mode.

Using the Diagnostics

The diagnostic file and an application that runs on Microsoft operating systems is
used to create a bootable diskette. Both files are available on the CD shipped with
the RocketModem IV. The diagnostic can be built using the CD menu system or
you can execute RModem/Diag/Rawrite.exe directly from the Comtrol CD.

Note: The application requires you to enter the disk image source file name. The

source file name is 1800055X.i; where X represents the revision letter of the
diagnostic.

Running the
Diagnostics

After creating a bootable diskette, use the following procedure to run the
hardware diagnostics:

1.

If the machine is on, power down the machine.

2.

Insert the diagnostic diskette you created in the diskette drive and power up
the machine.

3.

If necessary, configure your PC to boot from a diskette.

4.

When the title screen displays, press any key to start the diagnostic.

5.

Press any key to continue at the Please Note screen.

6.

At the RocketModem ISA TYPE SELECTION screen, select C if there are no
RocketModem/ISA boards installed, and Enter. If there are any RocketModem/
ISA boards installed, select the appropriate letter for that model.

7.

If the list of installed boards is correct, press Y and Enter.

Register

Range

Units

Default

Description

S0

0-255

Rings

0

Ring to answer on - ATS0=1<CR>
means answer call on 1

st

ring

detected

S1

0-255

Rings

0

Number of rings counted

S2

0-127

ASCII

43

Escape Code Character

S3

0-127

ASCII

13

Command terminator (Carriage
Return Character or the Enter
Key)

S4

0-127

ASCII

10

Line feed character

S5

0-127

ASCII

8

Back space character

S6

2-255

Seconds

2

Wait time for dial tone detection

S7

1-255

Seconds

50

Wait time for carrier

S8

0-255

Seconds

2

Pause time for coma in dial string

S10

1-255

.1sec

14

Loss of carrier to hang up delay

S11

50-255

.01sec.

95

DTMF tone duration

S12

0-127

1/50sec.

50

Escape Code Guard Time

S24*

0-255

1sec

0

Sleep Mode Inactivity Timer

S29

0-255

10mS

70

Hook flash dial modifier time (!)

S30

0-255

10sec.

0

Inactivity disconnect timer

S95

0

Result code control

Advertising