background image

16 - RocketModem IV: 2000468 Rev. A

Hardware Installation and Specifications

Hardware Specifications

Hardware Specifications

Modem Cables

RocketModem IV ports use standard telephone-
type unshielded twisted-pair cables with RJ11
modular connectors. These can be purchased
anywhere commercial telephone products are sold.

If you choose to build your own cables, use the
following information. When building cables, use a UL approved 26-gauge RJ11
telephone line cable or better. The connector pinouts are as shown below:

Environmental
Conditions

This table illustrates RocketModem IV environmental conditions:

Regulatory
Approvals

This table lists regulatory approvals.

RJ11 Pins

Signals

1 and 4

Not used

2

Ring

3

Tip

Pin 1

Pin 4

Environmental Conditions

Value

Air temperature:

System on

System off


0 to 60

o

C

-20 to 85

o

C

Altitude:

0 to 10,000 feet

Humidity (non-condensing):

System on

System off


8% to 80%

20% to 80%

Relative humidity (non-condensing:) 10% to 95%

Regulatory Approvals

Status

Emission:

Canadian EMC requirements ICES-003

CISPR-22:

European Standard EN55022

IEC 1000-3-2/EN61000-3-2: Harmonic

IEC 1000-3-3/EN61000-3-3: Flicker

FCC Part15 Subpart B: Class A limit

FCC Part 68 Certification

European TBR21 Compliant

Yes

Immunity: EN55024

IEC 1000-4-2: EN61000-4-2: ESD

IEC 1000-4-3: EN61000-4-3: RF

IEC 1000-4-4: EN61000-4-4: Fast Transient

IEC 1000-4-5: EN61000-4-5: Surge

IEC 1000-4-6: EN61000-4-6: Conducted disturbance

IEC 1000-4-8: EN61000-4-8: Magnetic field

IEC 1000-4-11: EN61000-4-11: Dips and Voltage Variations

Yes

Safety:

CSA C22.2 No. 60950/UL60950 Third Edition, UL & CUL
recognized.

Yes