Drawmer M500 Dynamics Processor User Manual

Page 31

Advertising
background image

M500 OPERATORS MANUAL

Ch 5 - 4

DE-ESS EXAMPLES

To do simple vocal DE-ESSing, select the desired channel to be DE-ESSed,
load the patch number

83

83 called

De S Vocal

De S Vocal. Hit THRESH and reduce the

sibilance to the required level by rotating the knob anti-clockwise. Adjust
the De-essing frequency hit FILTER and select the lowest (bottom)
screen page, adjust the filter to display the audio band that you wish to
compress.

For De-essing that does not attenuate the low frequencies that may be
present, load patch number

85 De S Music

85 De S Music into Channel 1. Apply a signal

to Channel 1 only. Hit THRESH and select Channel 1, the

ˆ

ˆ

D

D

indicator

under the input meter shows the maximum audio level that will pass
through the Channel 1 FILTER. Select Channel 2, the indicator is at +15dB
showing that the Ch2 audio is not compressed.

The

De S M

De S M

usic

usic patch 83 can also be very effective as a two band

compressor. Set Channel 1 OUTPUT

to

Auto

Auto and adjust the

DC MAKUP

Channel 1 THRESH indicator to

-30dB

-30dB. Set Channel 1's FILTER by using

the

LEFT and

RIGHT arrow keys to adjust the filtered band while

listening to some audio music source, adjust the DE-ESS

RLEASE

parameter to

50ms

50ms for drastic effect !

DE-ESS PATCHES

Patches numbered 81 through and including 89. Only patch number 83 can
process two audio channels, all others are

1<--

1<-- input and

1<--

1<-- output, (i.e.

Mono input and Mono output). See LINKS

ADVANCED GATE

Because the GATE incorporates several innovative features, the menu occupies five screens in
normal operation, the top one being as always the View Meters screen. The first screen page
down gives access to the more usual parameters of Threshold, Attack, Hold, Decay and Range.
This screen of parameters will be different if RECORDED envelope

is selected, to confirm

TYPE

this see the last (bottom) screen page.

GATE VIEW METERS

DOWN

GATE PARAMETERS FOR NORMAL TYPE

Sets a signal input level above which the GATE opens. The GATE

THRESH

THRESHOLD and the input level meter reads the level after the Filter if the
GATE

is set to

IntFilter

IntFilter or

ExtFilter

ExtFilter. The THRESHOLD

KeySOURCE

parameter ranges from

-50dB

-50dB to

+18dB

+18dB

Advertising