Drawmer Advanced Dynamics for Mackie D8B User Manual

Page 12

Advertising
background image

12

Drawmer ADX-100

Input Level Sliders
The input level sliders range from –13.75 dB to +18 dB.

Input Select
Assign the ADX-100’s stereo inputs and outputs from any of the
DB8’s pre or post inserts, or auxiliary send buses.

Menu Button
The pull-down menu button enables familiar D8B functions such
as undo, redo, load, save, reset, cut, copy, and paste.

Input and Output Meters
The Input Meters show the signal level after the input level
controls, so the OL indicator always warns of an actual overload.
The OL indicator remains on for 1 second following an input
overload. The Output Meters show the ADX-100’s output levels.
The level is controlled by the setting of the gain slider in the
compressor section.

Minimize Button
The small ‘x’ button at the top right will hide the plug-in
window, while the plug-in still remains loaded and active.

Preset Selection and Display
Toggle the up/down arrows to select from your own saved user
presets. You can also click directly in the display for the preset
drop-down list.

On/Off Button
Globally enables or disables the ADX-100. Signals pass through
the disabled ADX-100 dry and at unity gain.

Memory A/B
Memory A and Memory B are two separate storage banks that
let you temporarily store variations of settings. This is handy for
quickly referencing and comparing sounds while you are
creating edits.

Aux 6