Advanced features, Pump disconnect calibration night mode, Step 5) re-attach the pump to tank – EcoTech Marine Gen 2 MP40 User Manual

Page 4

Advertising
background image

Advanced Features

Step 2)

Press and hold Mode and Set to enter Setup. The

LED will blink red/white/blue

After programming Night Mode, the pump will enter Night Mode at the same time every day until the driver loses power. If the driver loses
power, Night Mode setting must be re-enabled. You can force a pump out of Night Mode by holding both Mode and Set. The pump will
automatically resume Night Mode at the original set time. Once you have forced a pump out of Night Mode, it can not be re-entered manu-
ally and you must wait until the original set time.

Pump Disconnect Calibration

Night Mode

Step 3)

Press and hold Mode and Set again to set Night

Mode. The LED will now switch to breathing white.

Step 1) Go into Feed Mode

Step 2) Remove pump from your tank

Step 3) Hold Mode and Set

Step 4) Let the program run

Enter Feed Mode by holding the Mode button for 3 seconds. Feed Mode is indi-
cated by a blinking white light.

Remove the motor and wet side assembly and set aside separately. Motor will still
be running so set it in a safe place with pin spacer facing upwards. (Do not con-

nect both halves of the pump!)

Holding both buttons while in feed mode will change the light from a blinking
white to a cycling white and yellow, this indicates that you have entered Calibra-
tion Mode.

The white and yellow cycling light will continue for about sixty seconds and then
the pump will restart.

Step 5) Re-attach the pump to tank

You have completed the Pump Disconnect Calibration and now have error codes
enabled

Enter the following button sequence to set Night Mode at the precise time when you desire your pump to enter into Night Mode. The
pump’s internal timer will then enter Night Mode for 10 hours and return back to your previous mode for 14 hours.

+

+

hold

+

hold

hold

hold

Remove

Pump

Wait

60sec

Re-attach

Your VorTech can automatically shut down in the event of a pump disconnect. To set-up this mode, you must calibrate
your motor using the following sequence of operations:

Night mode will operate at a constant speed of 50% of the day mode speed.

Reef Crest

Random

Constant

Speed Mode

Short Pulse

Mode

Constant

Speed Mode

Day Mode

Night Mode

Day Mode

Day Mode

80% of

max speed

40% of

max speed

100% of

max speed

50% of

max speed

g

g

Example 1

Example 2

Step 1)

Wait until the exact time that you wish night mode

to begin.

4