Digital outputs:

5 outputs (electromechanical relays):

-

1 SPST (K1) 30 A res. output @ 250 VAC for compressor

management

-

2 x 16 A res. outputs @ 250 VAC of which one SPDT (K2)

for management of defrosting and one SPST (K4) for

management of the door heating elements or of the

condenser fan

-

2 x 8 A res. outputs @ 250 VAC of which one SPST (KS) for

management of the evaporator fan and one SPDT (K5) for

management of the cabinet light, needle probe heating or

the UV light.

Type of actions and complementary

features:

1C.

Communication port:

1 TTL serial port with MODBUS communication protocol