8-2

8.1.1.1

Loopback

To incorporate the internal BERT functionality into the loop, select the BERT Enabled checkbox.

The general Network loopbacks are illustrated in the diagram below.

The general

Equipment

loopbacks are illustrated below.

Because of the Access Bank II architecture, not all loopbacks are available. If an unavailable loop-
back is selected, then the loopback not available dialog box is displayed.

Field

Input

Data Access

None, V.35, T1 #1, T1 #2

Direction

None, Equipment Line, Equipment Payload, Equipment TSI, Network
Line, Network Payload, Network TSI

X

BERT

TSI*

X

To/From

T1 Line

XMT

RCV

T1

Transmitter

T1

Receiver

Multiplexer

(TSI)

and

Framing

Circuits

Payload

XMT
DS0

RCV
DS0

*Time Slot Interchange: the cross-connection logic.

X

BERT

TSI*

X

To/From
DTE Equipment

(e.g., Router)

XMT

RCV

DTE

Transmitter

DTE

Receiver

Multiplexer

(TSI)

and

Framing

Circuits

Payload

XMT
DS0

RCV
DS0

*Time Slot Interchange: the cross-connection logic.