Offset, Smux proof, Interface category – Expert Sleepers Silent Way v2.4.3 User Manual

Page 50

Advertising
background image

The “Thru” input chooses a stereo pair of inputs which will receive a signal from another
Silent Way plug-in which is outputting a signal for the ES-4/5 e.g. from the ES-4 Control-
ler, from Silent Way Sync (in ES-4 mode) or from the Voice Controller (in ES-4 mode). Use
this input to stack plug-ins on a single track to address multiple ES-4/5/expanders at the
same time.

The drop-downs labelled “1” to “4” choose a plug-in input that will be routed to the corre-
sponding output of the ESX-4CV.

Offset

The “Offsets” controls let you dial in a voltage
offset on each ESX-4CV output. The values on
the controls are in Volts.

SMUX Proof

The ‘SMUX Proof’ button modifies the output of the plug-in to be
compatible with the

Silent Way SMUX

plug-in. It should be acti-

vated whenever the SW ESX-4CV Combiner’s output is being
passed through the SW SMUX plug-in, typically when running at double sample rates
(88.2/96kHz) with an Expert Sleepers ES-3 module.

Interface Category

The Interface Category drop-down menu allows you to inform the plug-
in of what kind of audio interface will be outputting the plug-in’s sig-
nal. Please refer to

http://expert-sleepers.co.uk/siwacategories.html

for more details - the specifics are likely to be more fluid than should be put here in the
user manual.