Assembly (continued), Installation – Campbell Hausfeld HX5101 User Manual

Page 3

Advertising
background image

3

HX5100, HX5101

www.chpower.com

assembly (Continued)

IntaKE fIltEr
Thread the intake air filter into the
threaded opening in the side of the
compressor head as illustrated in Figure
4. Tighten gently with a wrench.

figure 4 - Intake filter installation

Installation

loCatIon
It is extremely important to install the
compressor in a clean, well ventilated
area where the surrounding air
temperature will not be more than
100°F.
A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could obstruct
air flow.

Do not locate the

compressor air inlet

near steam, paint spray, sandblast areas
or any other source of contamination.
This debris will damage the motor.

ElECtrICal InStallatIon

All wiring and

electrical

connections should be performed by a
qualified electrician. Installation must
be in accordance with local codes and
national electrical codes.

WIrInG
1. Local electrical wiring codes differ

from area to area. Source wiring,
plug and protector must be rated for
at least the amperage and voltage
indicated on motor nameplate, and
meet all electrical codes for this
minimum.

2. Use a slow blow fuse or a circuit

breaker.

3. Make sure the product is connected

to an outlet having the same
configuration as the plug. This
product must be grounded. In the
event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire
for electric current. This product
is equipped with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be
plugged into an outlet that is
properly installed and grounded in
accordance with all local codes and
ordinances.

Overheating, short

circuiting and fire

damage will result from inadequate
wiring.

2. Place lock washer on axle bolt. Then

tighten nut securely to threaded
part of axle bolt.

3. Repeat procedure with other side.

lUBrICatIon

THIS UNIT IS

SHIPPED WITHOUT

OIL IN PUMP! Follow lubrication
instructions before operating
compressor.

Use oil shipped with the compressor. Do
not use regular automotive oil such
as 10W-30.
Additives in regular motor
oil can cause valve deposits and reduce
pump life. For maximum pump life,
drain and replace oil after the first few
hours of run time.
The compressor pump takes
approximately 280 ml (9.5 ozs.) of oil.
The sight glass, located on the crankcase
portion of the pump, is marked
with “max” and “min” levels. Avoid
overfilling by adding oil gradually and
checking the oil level with the sight
glass several times. Add enough oil to
reach the “max” level on the sight glass.
Proper oil level is illustrated in Figure 3.

figure 3 - proper oil level

Max.

Min.

figure 6 - Unit Identification

Intake filter

Oil fill / breather

Sight

glass

Handle

Oil drain plug

Drain valve

Check

Valve

Safety

Valve

Regulator

Exhaust

Tube

Pressure Switch

(Auto/Off)

Side view of unit

Top view of unit

Extension cords

length of Cord (ft)

25

50

100

Gauge of Cord

14

12

10

Advertising
This manual is related to the following products: