Operation (continued), Maintenance – Campbell Hausfeld HX5101 User Manual

Page 5

Advertising
background image

5

HX5100, HX5101

www.chpower.com

operation (Continued)

3. The safety valve should

automatically close at approximately
40 psi - 50 psi. If the safety valve
does not allow air to be released
when you pull on the ring, or if
it does not close automatically, it
MUST be replaced.

Safety valve must

be replaced if it

cannot be actuated or it leaks air after
ring is released.

prESSUrE GaUGES
Gauge attached to regulator indicates
air pressure going to hose (and any
tool attached to end of hose). Gauge
attached to pressure switch indicates air
pressure in tank.

Maintenance

Disconnect power source and
then release all pressure from
the system before attempting
to install, service, relocate or perform
any maintenance.

Check compressor often for any visible
problems and follow maintenance
procedures each time compressor is
used.
1. Turn compressor off and release

pressure from system. To release
pressure from system, pull ring on
ASME safety valve (see Figures 6 and
8). Deflect escaping air by shielding
valve with one hand as you pull ring
with other hand. Pull ring until tank
is empty.

A large amount of

fast moving air will

be released when the safety valve is
opened with pressure in the tank. Wear
ANSI approved Z87.1 safety glasses.

2. Drain moisture from tank by

opening drain valve (see Figure
6) underneath tank. Tilt tank to
remove all moisture.

3. Clean dust and dirt from tank,

air lines and pump cover while
compressor is still OFF.

oIl CHanGE
1. Allow compressor to run and warm

up oil. Unplug unit.

2. Position a pan under pump end of

unit.

3. Remove oil drain plug (see Figure 6).

Allow oil to collect in pan. Tilt unit
to completely drain.

4. Replace drain plug, fill pump to

full line on sight glass. Use Chevron
synthetic 5W-30, Mobil 1 5W-30 or
10W-30 synthetic motor oil. Using
other types of oil will cause starting
problems.

figure 9 - proper oil level

Max.

Min.

5. Change oil after every 50 hours of

use.

IntaKE aIr fIltEr MaIntEnanCE
Removal, Inspection and Replacement
(Figure 10)

figure 10 - Intake filter maintenance

Filter element

Filter cover

The intake filter element should be
removed and checked periodically.
A clogged intake filter can decrease
compressor performance and cause the
compressor to overheat.
1. Rotate the filter cover counter

clockwise and remove .

2. Remove the filter element and

inspect.

3. If the filter element is dirty or

clogged, replace it.

4. Reinstall filter and cover.
IMportant: Locate unit as far from
spraying area as hose will allow to
prevent overspray from clogging filter.

oVErloaD protECtor SECtIon

This compressor is

equipped with an

automatic reset overload protector
which will shut off motor if it becomes
overloaded.

If overload protector shuts motor OFF
frequently, look for the following
causes.
1. Low voltage.
2. Clogged air filter.
3. Lack of proper ventilation.

If the overload

protector is

actuated, the motor must be allowed to
cool down for 30 minutes before it will
reset.

StoraGE
1. Drain tank of moisture.
2. When not in use, store compressor in

a cool, dry place.

3. Disconnect hose and hang open

ends down to allow any moisture to
drain.