General description, Lcd display, Keyboard – Carrier DATACOLD 500 T/R User Manual

Page 4: 1 general, Description, 1 lcd, Display, 2 keyboard

Advertising
background image

1 General

description

The control panel of the DataCOLD 500 T/R consists of three main components:
1- LCD Display
2- Key board
3- Printer


1.1 LCD

Display

The display has four lines of information, showing the following content in the operating mode:

Page 4

62-61138-20 (02/03)






Line 1: Alarm active; temperatures, status of the digital inputs

 -23 –12 –08 –15 ✴

1:Return air –22.8

Wednesday 21/06/2000 13:47:05 W

Print Alarm Menu Status

Line 2: Rotating display of each temperature to an accuracy of 1
decimal point with sensor name.
Line 3: Day, date and time and indication summer/wintertime

NOTE: Date will be displayed as dd/mm/yyyy (as shown)

Line 4: Description of the actual button functions
In every other mode the content of the display is dependent on the
actual menu in use.

1.2 Keyboard

DataCOLD 500 T/R are completely menu controlled. All functions can be carried out via the four colored buttons
(like printing, activate alarms or change parameters). The actual function of the buttons are always displayed on
the bottom line. To navigate through the menu’s and change settings, two different kinds of button functions are
applicable.

To navigate through the menu’s and to select parameters in the edit mode, use the buttons as described below:


Blue

Next menu point

<

In edit mode: Next choice from table

Yellow

Previous menu point

>

In edit mode: Previous choice from table

Green

edit

Menu select, change to edit mode or one menu level down

accept

In edit mode: accept input and go to next menu point

Red

<-menu

One menu level up

<- cncl

In edit mode: Cancel changes and displays the non changed value. Press
and hold for 2 seconds to cancel changes and go back to previous menu.


When entering free programmable text, like names, the button functions are as follows:


Blue

Next character from the list

Yellow

Previous character from the list

Green

<

One character to the left

Red

>

One character to the right

Blue + Yellow

<- cncl

Cancel changes and displays the non changed value. Press and hold for 2
seconds to cancel changes and go back to previous menu.

Green + Red

accept

Accept input and go to next menu point.

Advertising