Ethernet and rs-232 control protocol – Contemporary Research IP IP-HDTV User Manual

Page 21

Advertising
background image

Contemporary

Research 21

IP-HDTV HD Tuner

Ethernet and RS-232 Control Protocol

Overview

The IP-HDTV full duplex Ethernet/RS-232 scheme enables a system programmer to control all TV Tuner

functions as well as monitor 3 groups of TV Tuner status. All commands are sent as ASCII strings. No delays

between characters or commands are required, as data is interrupt driven and buffered.

The 3 status groups are: Channel/Source Select, Audio Levels/Mode and Front Panel. The Mute A/V button-

function status from the IP-HDTV front panel has been grouped with the Channel/Source for simplicity in the

most common modes of operation. Each of the groups has one ASCII status response string containing all of

the status data for that group. The current status string of a group is sent from the IP-HDTV whenever a

valid command for that group is received by the IP-HDTV RS-232 port or front panel. A group's status may

be requested at any time via the RS-232 port. Status of all 3 groups is sent at power up. The format of each

group's status response string remains the same always.

Up to 9 IP-HDTV units may be cabled together and addressed for individual control from a single RS-232

port. Each IP-HDTV is assigned a unique unit code.

Communications parameters (Front Panel Mode 1) are 300 to 9600 baud, 8 data bits, No parity, and 1 stop

bit. Factory default is 9600 baud, Unit#1.

All settings are saved to NVRAM in the IP-HDTV.

The tuner will accept non-standard RS-232 control such as voltage that swings from 0 to +5 VDC, commonly

found when IR ports are used to send RS-232 commands.

General protocol specifications

Characters in command strings to the IP-HDTV are common ASCII keyboard characters.

Command strings sent to the IP-HDTV begin with the ASCII > (greater than symbol) as an 'Attention'

character and end with carriage return - ASCII CR, Hex $0D, or keyboard Enter - as an 'End-of-command'

character.

Responses from the IP-HDTV begin with the ASCII < (less than symbol) as an 'Attention' character and end

with a carriage return followed by line feed an ASCII LF or Hex $0A as 'End-of-command' characters.

A carriage return is required at the end of each command and is assumed in all examples.

Command String Structure

[Attention] (Unit#) [Command] (Parameters) [Return]

Attention

Single character (>) starts the string

Unit#

The Unit# is expressed as an ASCII 0-9 when used in multiple tuner applications.

To address all units, use a Unit # of 0 (Zero)

No unit number will default to Unit#1

Command

A two-character command

Parameters

Added attributes to some commands

Return

A carriage return ends the command string, you may use ASCII CR, Hex $0D, or keyboard

‘Enter’ in programming. For simplicity, the programming examples in the manual will not

show the ‘CR’ – so remember, you’ll need to add it in your control code.