Ixture, Inking, Data cabling – Chauvet ST-3000LED User Manual

Page 8

Advertising
background image

Setup

ST-3000LED User Manual

8

2009-12-10

/

14:04

F

IXTURE

L

INKING

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller

or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The

combined number of channels required by all the fixtures on a serial data link determines the number

of fixtures the data link can support.

The ST-3000LED fixtures use 3 channels of DMX control.

Important: Fixtures on a serial data link must be daisy chained in one single line. To

comply with the EIA-485 standard no more than 32 devices should be

connected on one data link. Connecting more than 32 fixtures on one serial

data link without the use of a DMX optically isolated splitter may result in

deterioration of the digital DMX signal.

Maximum recommended serial data link distance: 500 meters (1640 ft.)

Maximum recommended number of fixtures on a serial data link: 32 fixtures

Data Cabling

To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX

cables directly from a dealer/distributor or construct your own cable. If you choose to create your own

cable please use data-grade cables that can carry a high quality signal and are less prone to

electromagnetic interference.

D M X D a t a C a b l e

Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications.

Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will

have the following characteristics:

2-conductor twisted pair plus a shield

Maximum capacitance between conductors

– 30 pF/ft.

Maximum capacitance between conductor and shield

– 55 pF/ft.

Maximum resistance of 20

Ω / 1000 ft.

Nominal impedance 100 - 140

C a b l e C o n n e c t o r s

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.

CAUTION

Do not allow contact between the common and the fixture’s chassis ground.

Grounding the common can cause a ground loop and your fixture to perform

erratically. Test cables with OHM meter to verify correct polarity and to make

sure the pins are not grounded or shorted to the shield or each other.

COMMON

DMX +

DMX -

INPUT

OUTPUT

1

3

2

1

3

2

1

3

2

Resistance 120
ohm ¼ w between
pin 2 (DMX -) and
pin 3 (DMX +) of
the last fixture.

Termination reduces signal errors and
to avoid signal transmission problems

and interference, it is always

advisable to connect a DMX signal

terminator.

DMX connector configuration

Advertising