Loop back system, Idr-8 user guide 33 – Compex Systems AP4530 User Manual

Page 33

Advertising
background image

iDR-8 User Guide

33

Loop back system

This example shows two units

connected with the audio bus looped back from the last to the
first. This means that all inputs are available to both units using
the patchbays and matrix. Note that each unit must have its
own session of iDR System Manager running for configuration.

The loop back system uses the audio expander ports. In this
configuration these are no longer available for plugging in the
iDR-in and iDR-out expanders.

Force sync master Because it is not obvious to the

looped units which is the audio master, you need to manually
assign one of the units to be the sync master. If this is not
done then the operation of the units is unpredictable. Do this
from within the iDR System Manager session for the unit you
want to be the master, usually the first in the chain. Open the
File menu, Preferences, Synchronisation Options window. Tick
the Force Sync Master item.

To avoid feedback oscillation make sure you do not

route any output back to itself. Plan carefully how you will
use the input and output source patchbays and routing
matrix. Make sure all your patches are created to avoid
feedback problems.

ext

sync

lock

slave

96k

ext

sync

lock

slave

96k

FORCE SYNC MASTER

SYNC SLAVE

IN OUT

iDR Unit A

8A

7A

6A

5A

4A

3A

2A

1A

8

7

6

5

4

3

2

1

IN

OUT

IN OUT

iDR Unit B

8B

7B

6B

5B

4B

3B

2B

1B

8

7

6

5

4

3

2

1

IN

OUT

Advertising