Figure 5-23 – Cabletron Systems 2E48-27R User Manual

Page 97

Advertising
background image

High Speed Interface Configuration Screen

2E48-27R/2E49-27R User’s Guide

5-51

Figure 5-23

High Speed Interface Configuration Screen

The following briefly defines each field of the High Speed Interface
Configuration screen.

Port Type (Read-only)

Displays the type of interface (FE-100FX, FE-100TX, FE-100F3, or
Unknown) installed in ports 25 and 26.

Figure 5-23

shows that there is an

FE-100TX interface installed in port 25 and no interface (indicated by
Unknown) in port 26.

Link Status (Read-only)

Indicates whether or not there is a physical connection from this port to
another 10BASE-T or 100BASE-TX/FX device. One of the following
values displays:

Link There is a link signal present and a valid physical connection to
another device.

No Link There is no link signal present and no valid physical
connection to another device.

Firmware Revision: XX.XX.XX

High Speed Interface Configuration

23141-24

Device Type: 2E48-27R

BOOTPROM Revision: XX.XX.XX

Port 25

FE-100TX

Link

100Base-TXFD

[Auto-Negotiation]

[100Base-TXFD]

[Disabled]

RETURN

2E48-27R LOCAL MANAGEMENT

Event Message Line

SAVE

Port Type

Link Status

Current Oper. Mode

Desired Oper. Mode

Advertised Ability

Port 26

Unknown

N/A

[N/A]

[N/A]

[N/A]

EXIT

Advertising
This manual is related to the following products: