Misc configuration – Interlogix NS2503-24P/2C User Manual User Manual

Page 128

Advertising
background image

NS2503-24P/2C User Manual

128

Misc Configuration

In this page, you can change the default configuration for the 802.1x standard:

Figure 4-14-6:

802.1x Misc Configuration interface Screenshot


The page includes the following fields:

Object

Description

Quiet Period:

Used to define periods of time during which it will not attempt to acquire a
supplicant.
Default time is 60 seconds.

TX Period:

Set the period the port waits for retransmit next EAPOL PDU during an
authentication session.
Default value is 30 seconds.

Supplicant Timeout:

Set the period of time the switch waits for a supplicant response to an EAP
request.
Default value is 30 seconds.

Server Timeout:

Set the period of time the switch waits for a server response to an authentication
request.
Default value is 30 seconds.

Max Requests:

Set the number of authentication that must time-out before authentication fails
and the authentication session ends.
Default value is 2 times.

Reauth period:

Set the period of time which clients connected must be re-authenticated.
Default value is 3600 seconds.

Apply:

Press this button for changes to take affect.

Help:

Provide help information of 802.1x Misc Configuration.

Advertising