Programming your nx-588e – Interlogix NX-588E User Manual

Page 2

Advertising
background image

2

NX-588E USB Flash Programmer Installation Instructions

8. Click OK, and then click Next.

9. A screen appears indicating that the driver has not passed

a Windows certification test. Select Continue anyway.

10. Click Finis h.

Programming your NX-588E

Program your NX-588E so the settings you choose in the

DL900 software download onto your NX-588E and onto the

control panel. You can do this directly from your PC or first to

your NX-588E and then on to your control panel.

Using the DL900 software to connect to your panel

To directly download a configured template to the control

panel, use the NX-588 as an interface by doing the following:

1. Connect the NX-

588E to the PC’s USB port.

2. Connect the cable, from the NX-588E to a NetworX panel

using alligator clips:

Red to POS

Black to COM

Green to DATA

3. Start the DL900 download software.

4. Select the account to use.

5. Select Download/Direct connect. You can also use the tool

bar or the F11 key.

Note: DL900 software version 2.20 or newer autodetects

the NX-588E.

6. A DL900 window displays when the NX-588E is detected.

If you don’t want the window to display in the future select

the Do not show this screen again option and click OK.

7. Download as normal.

Writing DL900 files to the NX-588E

To write data from the DL900 to the NX-588E, do the following:

1. Connect the NX-

588E to the PC’s USB port.

2. Start the DL900 download software.

3. Select Download/Write panel data to 586/588. The system

warns you that this will overwrite user codes (if you have

changed them).

4. A DL900 window displays indicating NX-588E detection. If

you don’t want the window to display in the future select

the Do not show this screen again option and click OK.

5. Select the location in the NX-588E where you want the

data stored. This overwrites the existing data and does not

prompt you in the future.

A screen prompts you that the data is being read. The process

is complete when this screen closes.

Note: Programming information for the modules is not read or

written to or from the NX-588E.

Reading data from the NX-588E to the DL900

To read data from the NX-588E to the DL900, do the following:

1. Connect the NX-

588E to the PC’s USB port.

2. Select Download/Read panel data from 586/588 to start

the DL900 download software.

3. A DL900 window displays indicating NX-588E detection. If

you don’t want the window to display in the future select
the Do not show this screen again option and click OK.

4. Select the location, in the NX-588E, where you want to

retrieve data from.

A screen prompts you that the data is being read. The process

is complete when this screen closes.

Note: Programming information for the modules is

not

read or

written to or from the NX-588E.

Uploading a configuration file to the alarm panel

To upload a configuration file directly from the NX-588E to the

panel, without a computer, do the following:

1. Attach the cable to the proper terminals on the NX panel

using three alligator clips. See “Using the DL900 software
to connect to your panel

” above.

2. If you have a keypad installed in partition 8, keypad 8, you

must remove it during this operation.

3. Enter *, 8 on a partition 1 keypad.

4. Enter the 4- or 6-digit program code. (Default is 9713.)

5. Enter 2, 5, 5, # when prompted for the device number.

6. Enter 0, # when prompted for the location. See Table 1

below for a complete list of tasks and results.

7. To read (store the NX panel configuration into a file on the

NX-588E), do the following:

Enter 1, *.

Enter the number of the file (1 to 4) in which you wish to

save it.

Enter *, #.

Table 1: Segm ent 1 tasks and results

Tas
k

Result

0

Idle condition.