5812-RND Acoustic Glassbreak Detector

Figure 9. Testing the Range

GND +12V N.C. COM

Figure 7. Wiring Terminals

• Single

• Contin

uous

Plate •

T

empered •

Laminated •

Batter

y LED

Batter

y is OK if LED

sta

ys on during test

5709C

Shatter Series

T

ester

Use f

or testing:

ShatterPr

o

Shatterbo

x

Shatterbo

x II

ShatterSwitc

h

SENTR

OL

Figure 8. Using the Tester

When the detector is in test

mode, the LED lights steady for

4 seconds, then flashes for 60

seconds. Time resets after

each valid test.

Hold the tester so that the

speaker is within 1” (2.5cm) of

the detector microphone.

1” (2.5cm)

Testing the Detector

Testing the Detector

Testing the Detector

Testing the Detector

Testing the Detector

To verify detector range and operation, you need the
Sentrol 5709C hand-held tester.

Use the following steps to test the detector:

1. Set the tester to the appropriate glass-type setting.

Use the tempered setting if you are unsure about the
glass type.

2. Put the detector in test mode as follows:

- Hold the tester 1” from the detector. See Figure 8.

- Activate the tester.

The LED on the detector lights for 4 seconds and then
starts flashing to indicate the detector is in test mode.
The relay opens for 4 seconds, then returns to
standby.

3. Hold the tester near the surface of the glass to be pro-

tected and aim the speaker at the detector. Be sure the
tester is at the point on the glass farthestfrom the
detector. If closed drapes or curtains are present, hold
the tester behind them. See Figure 9.

4. Press the test button on the tester. The LED on the

detector should stay on for 4 seconds to indicate the
glass is within detection range of the detector. If the
LED does not stay on for 4 seconds
, move the detector
and retest.

Understanding the LED

The red LED located on the front of the detector
indicates the status of the unit as follows:

Status

LED Indication

Power on

Flashes once when power is applied.

Clap test/Alarm

In response to the clap test:

memory

Flashes twice to indicate the detector has
power and is functioning properly.

o r

On for 4 seconds to indicate the detector
has alarmed.

Alarm

On for 4 seconds with relay when
breaking glass is detected.

Test mode

On for 4 seconds with relay, then flashes
for 60 seconds. Each test trigger resets
the test mode clock and the LED starts

over flashing for 60 seconds.