5812-RND Acoustic Glassbreak Detector

Using the Hand-Clap Test and
Alarm Memory

The alarm memory and microphone operation can be
checked with the hand-clap test as follows:

1. Standing under the detector, clap your hands together.

2. Observe the LED on the detector.

If the detector has power and is functioning properly, the
LED quickly flashes twice.

If the detector has alarmed, the LED will light for 4 seconds.
Cycle the power to clear the alarm memory.

The hand-clap test is intended as a functional test, does not
open the relay, and is not an accurate indication of detector
range.

Maintaining the Detector

When installed and used properly, the detector provides
years of service with minimal maintenance. You should test
the detector annually to ensure proper operation.
Clean the cover with a damp (water) cloth as needed to keep
it free of dust and dirt. Always test the detector after
cleaning.

FCC Compliance

This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.

(2) This device must accept any interference received,
including interference that may cause undesired operation.

Specifications

Input voltage ........................................ 12 VDC Nominal
Current
Typical ................................................................ 15mA
Maximum ............................................................. 25mA
Electrical configuration ........................................ Form A
Relay rating ............................................. 16V, 50mA max.
Detection range .................... 5’ - 25’ (1.5m - 7.6 m) x 360°
(use for rooms 100 sq. ft. and larger)
Alarm response ...................................................... 4 sec.
Minimum glass size ............... 12” x 24” (30.5 cm x 61 cm)
Recommended glass thickness:
Plate ................................ 3/32” - 1/4” (2.4 mm - 6.4 mm)
Tempered ......................... 1/8” - 1/4” (3.2 mm - 6.4 mm)
Wired ....................................................... 1/4” (6.4 mm)
Laminated ................................................ 1/4” (6.4 mm)
Operating temperature ................. 32° - 122° F (0° - 50°C)
Relative humidity ................... 10 - 90% non-condensing
Dimensions:
Depth ...................................................... 0.81” (2.1 cm)
Diameter .................................................. 4.0” (10.2 cm)
Color ..................................................................... White
Field wiring size ............................................ 18-24 AWG
Listing ............................................................... C-UL US

1038240 Rev A 06/02

12345 SW Leveton Drive

Tualatin, OR 97062

www.interlogixsecurity.com

www.sentrol.com

© 2002 GE Interlogix, Inc.

Phone: 503-692-4052

USA & Canada: 800-547-2556

Technical Service: 800-648-7424

FaxBack: 800-483-2495

GE Interlogix

Product Ordering

Model Number

Description

5812-RND

Acoustic glassbreak sensor, round housing, Form A

Accessories
5709C

Glassbreak hand-held tester