Maintenance and testing – Interlogix Wireless Personal Panic Device User Manual

Page 3

Advertising
background image

P/N 466-4431

• REV B • 14FEB14

3 / 4

2.

When prompted, enter the appropriate
group number and select the desired
sensor number.

3.

Press the help button on the Personal
Panic Device to trip the selected
sensor.

4.

Exit from Program Mode.

Maintenance and Testing

Testing

Review the following for testing the help
button. Refer to the specific panel
Installation Instructions
for further detail.

1.

Set the panel to Sensor Test Mode.

2.

Press and hold the help button for a
second to monitor the beeps for the
packet count.

3.

Listen for the panel siren. You should
hear 6 to 8 beeps.

4.

Test the help button from several
locations to ensure a consistent
response.

5.

Test the help button weekly to ensure
proper operation.

6.

Verify the end-user can operate the
unit without any difficulty.

Cleaning

1.

Gently rub a lanoline-based cleaner,
such as Go-Jo, onto all surfaces of the
Personal Panic Device to remove any
debris.

2.

Rinse off using warm water.

3.

Wipe clean using a dry, lint-free cloth.

Replacing the Battery

CAUTION: To avoid an alarm
condition set the panel to Sensor Test
Mode
prior to changing the battery.
Pour éviter une condition d'alarme
metter le panneau en Mode d'essai
des capteurs avant de changer la
batterie.

CAUTION: Use static electricity
precautions when handling electronic
components.
Utiliser les précautions de l'électricite
statique lors de la manipulation des
composants électroniques.

1.

Depending on the situation, it may be
necessary to contact the central
monitoring station before starting the
installation.

2.

Remove the two screws on the back of
the Personal Panic Device and
observe how the pendant or wristband
components are attached.

3.

Carefully separate the cover and base.

4. Remove the electronic subassembly

from the base.

5.

Remove the battery from the electronic
subassembly.

6.

Install the new battery. Observe
polarity.

Note: Install Panasonic CR1632.

7.

Place the electronic sub assembly into
the base. Note: A generic diagram is
shown above. For diagrams showing
the wristband and pendant
configurations, see the assembly
diagrams in the “Installation/Pendant
section.

8.

Inspect the water seal area and the
plugs to ensure they are free from
debris.

9.

Reattach the cover, lanyard assembly
or wristband and the base. Note:

Advertising