Cisco 7200 VXR Installation and Configuration Guide

OL-5013-09

Chapter 1 Cisco 7200 VXR Product Overview

Functional Overview

Following is sample output of the show environment last command:

NPE300(boot)# show environment last

chassis inlet previously measured at 26C/78F

chassis outlet 1 previously measured at 28C/82F

chassis outlet 2 previously measured at 29C/84F

chassis outlet 3 previously measured at 33C/91F

+3.45 V previously measured at +3.46

+5.15 V previously measured at +5.23

+12.15 V previously measured at +12.24

-11.95 V previously measured at -11.81

last shutdown reason - power supply shutdown

The show environment table command displays the temperature and voltage thresholds for each
temperature sensor and for each monitored status level. These thresholds are related to those listed in

Table 1-36

and

Table 1-38

. The display also lists the shutdown threshold for the system.

Following is sample output of the show environment table command for a Cisco 7206VXR that has an
installed NPE-300:

NPE300(boot)# show environment table

System shutdown for chassis inlet is 75C/167F

System shutdown for chassis outlet 1 is 58C/136F

System shutdown for chassis outlet 2 is 75C/167F

System shutdown for chassis outlet 3 is 65C/149F

Note

Temperature ranges and values are subject to change.

The show environment all command displays an extended report that includes temperature readings and
voltage readings. The show environment all command also displays a report showing which power
supply slots are occupied and which are empty.

Sample Point

chassis inlet

chassis outlet 1

chassis outlet 2

chassis outlet 3

+3.45 V

+5.15 V

+12.15 V

-11.95 V

LowCritical

+3.26

+4.86

+11.39

-9.52

LowWarning

+3.34

+4.99

+11.67

-10.73

HighWarning

40C/104F

43C/109F

75C/167F

50C/122F

+3.55

+5.31

+12.62

-13.16

HighCritical

50C/122F

53C/127F

75C/167F

60C/140F

+3.63

+5.43

+12.91

-14.38