OPERATING INSTRUCTIONS

• Risk of electric shock. Connect this product only to a grounding type receptacle

protected by a ground-fault circuit interrupter (GFCI) or residual current device (RCD).

Contact a qualified electrician if you cannot verify that the receptacle is protected by a

GFCI/RCD. Use a qualified electrician to install the GFCI/RCD, which has a maximum

rate of 30mA. Do not use a portable residual current device (PRCD).

To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors

or converter plugs to connect unit to electric supply; provide a properly located outlet.

Do not attempt to plug in or unplug this product while standing in water or when your

hands are wet.

• Never operate this product above the maximum working pressure stated on the filter

tank.

• Always switch off pump before changing the 6-way valve position.

• Operating this product without water flowing through the system can cause a build up

of hazardous pressure which can result in an explosive situation, serious injury,

property damage or death.

• Never test this pump with compressed air. Never operate the system with water

temperature above 35° C (95° F).

Valve Position

Function

Water Flow Direction

FILTER

(see drawing 23)

Normal filtration and regular vacuuming

of pool

From pump through filter media to

pool

BACKWASH

(see drawing 24)

Reverses water flow to clean filter

media

From pump through filter media to

valve waste/drain outlet

RINSE

(see drawing 25)

For initial startup cleaning of the sand, and

leveling the sand bed after backwashing

From pump through filter media to

valve waste/drain outlet

WASTE

(see drawing 26)

For vacuuming directly to waste,

lowering pool level or to drain the pool

From pump to valve waste/drain

outlet bypassing the filter media

RECIRCULATE

(see drawing 27)

For circulating water back to pool

without going through the filter media

From pump through valve to

pool bypassing the filter media

CLOSED

(see drawing 28)

Shuts off all flow to filter and pool

“Do not use this setting with pump running”

6-way valve positions and function: