Troubleshooting guide, Specifications – Cobra Electronics CPI 475 User Manual

Page 10

Advertising
background image

15

14

Troubleshooting Guide

Operation

Specifications

Operation

Specifications

Continuous output power (1 hour) . . . . . . . . . . . . 400W

Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . . 800W

Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88%

Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83%

No load current draw . . . . . . . . . . . . . . . . < 0.5A (12.6V)

Output waveform (resistive load) . . . Modified sine wave

Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ

Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V

USB output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V

Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC

Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V

Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V

Operating temperature range . . . . . . . . . . . . 0°C – 40°C

(32°F – 104°F)

Storage temperature range . . . . . . . . . . . . -40°C – 85°C

(-40°F – 185°F)

Protection . . . . . . . . . .Overload, short-circuit, overtemp,

reverse polarity, under/over voltage

Notes

All protection is automatically recovered.

To protect the battery, if the unit needs to be restarted
after low voltage protection, the voltage of DC input
should be above 12V.

To extend the life of the fan, it will stop when there is no
load. The speed of the fan increases as the load increases.

The unit is completely insulated in input and output for
added safety.

Problem/Symptom

Low output voltage

No output voltage

No output voltage
after prolonged use

No output voltage,
“Protect” indicator
lighted

No output voltage

No power to
inverter

Low battery alarm
on all the time

Possible Causes

Overload

Low input voltage

Thermal
shutdown

High input
voltage

Short circuit

Blown fuse

Poor DC wiring

Poor battery
condition

Solution

Reduce the load.

Recharge battery.
Check connections
and cable.

Allow inverter
to cool off.

Reduce load,
continuous
operation input
current required.

Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed.

Reduce ambient
temperature.

Make sure
the inverter is
connected to
12V battery.

Check regulation
of charging system.

Check load for
proper operation.

Replace fuse.

Check
connections.

Make sure battery
is fully charged.

Troubleshooting Guide

Nothing

Comes Close to a Cobra

®

10272-CPI475_PH2.qxd 7/9/07 11:30 AM Page 14