Wiring diagrams, Figure 5, Figure 6 – Chromalox UB-502D User Manual

Page 3: Figure 7, Figure 8

Advertising
background image

WIRING DIAGRAMS

}

C1
T1
T2

F1
F2

L1

L2
L3

Alternate 240V Wiring

Integral 480V/240V

or 120V Transformer

Thermal

Cutout

Ground

Heater Bank

1Ø Motor

Heater

Wiring Comp't

Baffle

For 3 Phase Only

120V Wiring

X1

X3

X2

X4

X1

X3

X2

X4

H1

H2

This Wiring

by Customer

Control

Switch Optional

Thermostat
When Used

Contactor

Fused

Switch

1 or 3 Phase 60 Hz

Power Supply 480 Volts

Figure 5

Use with:

UB-502D-T &
UB-752D-T
480V, 1Ø or 3Ø

Integral

Contactor

Ground

Heater Bank

1Ø Motor

Heater

Wiring Comp't

Baffle

For 3 Phase Only

}

This Wiring

by Customer

Thermostat
When Used

Control

Source 120 or

240 Volts, 60 Cycle

1 or 3 Phase 60 Hz Power
Supply 208, 240 or 480 Volts

Fused

Switch

Cutout

Fused

Control Switch

C1

C2
L1

L2
L3

Figure 6

Use with:

UB-502D-R &
UB-752D-R
480V, 1Ø or 3Ø

Alternate 240V Wiring

Integral 480V/240V

or 120V Transformer

Integral

Contactor

Ground

Heater Bank

1Ø Motor

Heater

Wiring Comp't

Baffle

For 3 Phase Only

120V Wiring

X1

X3

X2

X4

X1

X3

X2

X4

H1

H2

}

This Wiring

by Customer

Thermostat
When Used

Control

Switch Optional

1 or 3 Phase 60 Hz Power
Supply 480 Volts

Fused

Switch

Cutout

T1
T2
C1

C2
L1

L2
L3

Figure 7

Use with:

UB-502D-TR &
UB-752D-TR
480V, 1Ø or 3Ø

Integral

Contactor

Ground

Heater Bank

1Ø Motor

Heater

Wiring Comp't

Baffle

For 3 Phase Only

}

This Wiring

by Customer

Thermostat
When Used

1 or 3 Phase 60 Hz
Power Supply 208 or 240 Volts

Fused

Switch

Cutout

T1

T2

L1
L2
L3

Figure 8

Use with:

UB-502D-R
208V, 1Ø or 3Ø
240V, 1Ø or 3Ø

UB-752D-R
208V, 3Ø
240V, 3Ш

Advertising