Installing the VoIP Loudspeaker Amplifier

VoIP Loudspeaker Amplifier Operations Guide

930106A

CyberData Corporation

13

2.3 Configure the Loudspeaker Amplifier Parameters

To configure the loudspeaker amplifier online, use a standard web browser.

Configure each loudspeaker amplifier and verify its operation before you mount it. When you are
ready to mount a loudspeaker amplifier enclosure, refer to

Chapter 3, “Mounting the Enclosure”

for

instructions.

All loudspeaker amplifiers are initially configured with the default IP settings indicated in

Table 2-7

.

When configuring more than one loudspeaker amplifier, attach the loudspeaker amplifiers to the
network one at a time to avoid IP address conflicts.

2.3.1 Log in to the Configuration Home Page

1. Open your browser to the speaker IP address.

For the initial configuration of the speaker, open your browser to the default IP address:

http://192.168.3.10

Note

Make sure that the PC is on the same IP network as the loudspeaker amplifier.

2. When prompted, use the following default Web Access Username and Web Access Password

to access the Home Page (

Figure 2-9

):

Web Access Username: admin

Web Access Password: admin

Table 2-7. Factory Default Settings

Parameter

Factory Default Setting

IP Addressing

static

IP Address

192.168.3.10

Web Access Username

admin

Web Access Password

admin

Subnet Mask

255.255.255.0

Default Gateway

192.168.3.1