360 dvs series direct vent fireplaces, Mantels, Clearance to combustibles – Vermont Casting 360DVSL User Manual

Page 8: Hearth

Advertising
background image

8

360 DVS Series Direct Vent Fireplaces

10006326

Appliance

Top ......................................... 0” (0mm) to standoff
Bottom ..................................................... 0” (0mm)
Vent End ....................... 1/2” (13mm) to rear panel
Nonvent End (DVS2) ............................... 0” (0mm)

Venting
Concentric sections of DV Vent:

Top, bottom & sides ............................... 1” (25mm)

Nonconcentric sections of DV Vent:

Side and bottom .................................... 1” (25mm)
Top ......................................................... 2” (51mm)

Mantels

The height at which a combustible mantel is fitted
above the fireplace is dependent on the depth of the
mantel. This also applies to the distance between the
mantel leg (if so fitted) and the fireplace. For correct
mounting height and width, refer to Fig. 4a and 4b and
the Mantel Chart below.

The fitting of a bay window trim kit does not affect the
distances and reference points referred to in the
diagram and chart.

Noncombustible mantels and legs may be installed at
any height and width around the appliance.

When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.

Clearance to Combustibles

A

B

C

D

E

V

W

X

Y

Z

Louvre Assembly
Top

Fireplace

Top of Combustion
Chamber

Bottom of Door Trim

Mantel Shelf

Mantel from Top

Ref.

or Breast Plate

Ref. of Comb. Chamber

V

10” (254mm)

A

19” (483mm)

W

8” (203mm)

B

17” (432mm)

X

6” (152mm)

C

15” (381mm)

Y

4” (102mm)

D

13” (330mm)

Z

2” (51mm)

E

11” (297mm)

Mantel Chart

CFM146

Fig. 4a Combustible mantel minimum installation.

J

F

G

H

I

Top View

Mantel Leg

CFM197

O

N

M

L

K

Front View

Side of Combustion
Chamber

Mantel
Leg

CFM170

Mantel

Mantel Leg From Side

Ref.

Leg Depth

Ref.

of Comb. Opening

F

10” (254mm)

K

11

¹⁄₂

” (292mm)

G

8” (203mm)

L

9

¹⁄₂

” (241mm)

H

6” (152mm)

M

7

¹⁄₂

” (191mm)

I

4” (102mm)

N

5

¹⁄₂

” (140mm)

J

2” (51mm)

O

3

¹⁄₂

” (89mm)

Fig. 4b Combustible mantel leg minimum installation.

A hearth is not mandatory; however, for aesthetic
purposes, we recommend installing a noncombustible
hearth that projects out 12” (305mm) or more from the
front of the fireplace.

Cold climate installation recommendation:

When installing this unit against a
noninsulated exterior wall or chase, it is
mandatory the outer walls be insulated to
conform to applicable insulation codes.

Hearth

Advertising
This manual is related to the following products: