Warning, Caution – Carrier INFINITY 2025 User Manual

Page 5

Advertising
background image

5

Furnace

Airflow

Airflow

Adapters

A05274

Fig. 5 -- Use of Furnace Adapters

Note (optional): Slip return

duct adapters onto flanges

on air return duct side

A05277

Fig. 6 -- Use of Return Duct Adapters

Step 9

—Wiring

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than 1 disconnect

switch.

!

WARNING

EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment

damage or improper operation.
This unit cannot be powered directly from blower motor

leads. Voltages can exceed 190 VAC (120v motors). Do

not wire directly to blower motor. Wiring to blower motor

will damage power supply and void warranty.

CAUTION

!

a. Ensure power has been removed from the heating and

cooling system.

b. Turn the Infinityt Air Purifier power switch off.

c. Connect the power cord to the power supply connector

(see Fig. 7).

d. Route the power cord through nearest cabinet hole and

protect with enclosed cable connector. Zip ties have

been enclosed to secure the power cord to the side of the

power supply.

e. Attach the quick connect terminals to the furnace

EAC--1 and EAC--2 spade connections. Attach the

ground ring to furnace chassis ground.

NOTE: The Infinityt Air Purifier is to be powered by 115v/60
Hz.

NOTE: The Infinityt Air Purifier should only be powered when
airflow is present. The furnace control EAC spade connections
provide power only when the furnace blower is operating. If EAC
connections are not available, an alternative airflow sensing
mechanism must be used to ensure the Infinityt Air Purifier is
only powered when airflow is present. Contact a local Carrier
distributor for information on approved alternatives.

UNIT COMPONENT DAMAGE HAZARD
Failure to follow this caution may result in equipment

damage or improper operation.
Black Lead -- Connect to HOT (L1) or EAC--1 when

provided.

White Lead -- Connect to Neutral (L2) or EAC--2 when

provided.

Green/Ground Lead -- Connect to Appliance Ground

(Chassis)

CAUTION

!

GAP

A

Advertising