Warning, Start--up and operation, Maintenance – Carrier INFINITY 2025 User Manual

Page 6: Gap a, Fig. 8 -- power indicator

Advertising
background image

6

Sample Furnace Circuit Board

Power Cord

to EAC Terminals

Alternate Power Cord

Pass-Thru Hole

Use cable connector to secure

power cord to cabinet

Power Supply Connector

Power Supply

Use wire ties to secure power cord

to power supply enclosure

LHT
OFF
DLY

ON

OFF

W2

BLW

EAC-1 TERMINAL

Y1

DHUM

G

COM

24V

WW1

Y/Y2

R

TEST/TWIN

HUM

1 2 3

PL
T

A

CRDJ

0.5-AMP024 VAC

FUSE 3-AMP

SEC-1

SEC-2

PL1

NEUTRAL-L2

1

EAC-2

BHT/CLR

BHI/LOR

PL3 1

BLWR

COOL

SPARE-1

SPARE-2

1-AMP@115 VAC

EAC-1

PR-1

IDR

HSIR

IDM

IHI/LOR

PL2

1

HSI HI LO

STATU

S

C

OD

EL

E

D

EAC-2 TERMINAL

HI HEA

T

LO HEA

T

L1

Use terminals to connect the

power cord wires to the furnace

EAC-1 & 2, & ground terminals

Power Supply Connector

Power Cord

A06030

Fig. 7 -- Infinityt Air Purifier Electrical Connections

START--UP AND OPERATION

Step 1

—Checking Air Purifier Operation

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal

injury or death.
Before installing or servicing system, always turn off

main power to system. There may be more than one (1)

disconnect switch.

!

WARNING

a. Attach the Infinityt Air Purifier door to the cabinet. A

magnet in the door (see Fig. 9) is used to activate a safe-

ty switch in the power supply when the door is installed.

The power supply will not energize the air purifier un-

less the safety switch is activated.

b. Turn the HVAC system power on and adjust the

thermostat or Infinityt System Control to activate the

system fan.

c. Turn the Infinityt Air Purifier power switch to on

position.

d. The power indicator light above the Air Purifier power

switch should illuminiate (see Fig. 8).

e. Check to ensure the light goes off when the Infinityt

Air Purifier power switch is set to off, when the blower

goes off, or when the HVAC system power is turned off.

Step 2

—Infinity Control

a. When the Infinityt Air Purifier is used with an Infinity

Control, the Infinity Control can be configured to

remind the homeowner when it is time to change the

Infinityt Air Purifier cartridge. This maintenance

reminder can be based on either the TrueSenset dirty

filter algorithm or time. The installer should use their

discretion to select the most appropriate option based on

the initial system static pressure.

Step 3

—Maximizing Performance

a. Maximum air purification performance is obtained

when the furnace blower is set for continuous operation

on the thermostat or Infinity Control.

Power Indicator

A06052

Fig. 8 -- Power Indicator

MAINTENANCE

The Infinityt Air Purifier is designed to require no cleaning.

Maintenance is limited to the replacement of the air purification

cartridge. Frequency of air purifier cartridge replacement may

vary depending on ductwork design and local environmental

conditions.
To replace the air purifier cartridge, complete the following

steps:
Step 1

Turn the heating and cooling system off.

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal

injury or death.
Before installing or servicing system, always turn off

main power to system. There may be more than one (1)

disconnect switch.

!

WARNING

GAP

A

Advertising