4. INSTALLATION PROCEDURES

A. Connect the 1/4”OD tubing between water inlet of chiller and the supply water hose with pressure

rating suitable for use with the application. The tubing must be acceptable for use with potable
water.

B. Using the 1/4”OD tubing included with the (gooseneck) faucet, connect on water outlet of chiller.

-Flush water in lines before installing gooseneck faucet.
-Acceptable supply water pressure is 15~100 PSI (100~700kPa)

CAUTION: TO PREVENT PROPERTY DAMAGE DUE TO WATER LEAKAGE, SEEK INSPECTION BY

PLUMBERS TO SEE THE WATER PRESSURE IS LESS THAN 100PSI (690KPA) BEFORE YOU CONNECT

THE SUPPLY WATER HOSE.

C. Slowly open supply water valve. By opening faucet lever, let water flows for about one minute.

Check all the connections.
-Purge off all air from all water lines by opening faucet lever. Steady stream assures all air is
ventilated.

D. Prior to drinking, flush water through chiller for at least 5 minutes.
E. Check the available power supply against the chiller data plate to assure correct electrical service.
F. Plug in chiller and the chiller will be ready to serve you cold water in 30 minute after installation

CAUTION: FAILURE TO ABIDE BY ABOVE PROCEDURE CAN CAUSE PHYSICAL DAMAGE ON THE

COOLER.

5. STORAGE

A. Unplug power cord.
B. Open faucet until water is room temperature.
C. Close the source water valve.
D. Disconnect the water pipe from the product.
E. Place a bucket beneath the drain pipe. Open the drain cover and cap. Then, drain the remaining

water.

F. When storing, ensure it stands on its erect position on the flat and even ground. (Do not lay the

product on its sides down or upside down.)

G. When not use for a long period of time, conduct product cleaning before you put in storage.

CAUTION: FAILURE TO ABIDE BY ABOVE PROCEDURE MAY INCUR PHYSICAL DAMAGE ON THE

COOLER.

7. TROUBLESHOOTING GUIDE