Noise, Water leakage, Others – Clover Electronics C12E User Manual

Page 8

Advertising
background image

8


thermostat may be defective.

Replace the thermostat.

The thermostat is improperly set for the
prevailing environmental conditions and
cooler usage.

Adjust the thermostat.

short running cycle. It
is cooling, but does not
run long enough to
cool water to the
required level.

The compressor motor is defective,
causing the cooler to cycle on the overload
protector.

Replace the compressor.
Return cooler to authorized service center
or factory for repair.

F. A. The cold water
flows slowly or not at
all.

The cold water thermostat is so much low,
causing ice to build up in the reservoir,
blocking water flow.

Defrost cooler.
Adjust the temperature control.

NOISE

The cooler is not level.

The cooler must be leveled.
Place the cooler on even surface.

A section of the tubing inside the
cooler is touching other parts of cooler,
causing noise to be generated due to
vibration.

Adjust position of the tubing to make
sure it is not in contact with any other
parts.

Check the connection of the fixed
screws.

Completely connect the fixed screws.

A. There is
excessive noise
coming from the
cooler, but it is
otherwise operating
normally.

The compressor's operation is noisy
because of inherent conditions.

Advise the customer of the cooler's
normal operating sounds.

WATER LEAKAGE

A. Leakage through
inside of appliance

The cold water tank leaks.

Return chiller to authorized service
center or factory for repair.

OTHERS

Mineral concentration of supplied water is
somewhat high.

This product does not include filters.
Change the existing filter or use a proper
one.

A. Odd taste and
smell in Water

No use for a long time.

Continue to let the water flow until it runs
clear.

When using a water pressure regulator.

Adjust a regulator according to it’ manual or
contact a qualified engineer.

B. Strong water flow

Supplied water pressure is set up too high
originally.

Install a regulator that can control the
pressure or contact a qualified engineer.