Spi status words, machine 1, Spi s, Tatus – Conair MPA User Manual

Page 79: Ords, Spi c, Ppendix, Status, machine 1

Advertising
background image

UGH004/0999

C

HILLER

SPI C

OMMANDS

A

PPENDIX

B-3

Status, Machine 1

Poll: 0x21 0x42

SPI STATUS WORD

Word BIT position

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

EEprom error

SET SET

*

A/D converter error

SET SET

*

CJC Error

SET SET

*

RAM hardware

SET SET

*

ROM checksum

SET SET

*

Probe Failure

*

E/M Hi temp safety

SET SET

SET

*

Prog. Hi temp safety

SET

SET SET

*

Output monitor failure

SET

SET

*

Low water pressure

SET

SET

SET

*

High deviation alarm

*

Low deviation alarm

*

Prog. Lo temp safety

SET

SET SET

*

Pump overload

SET

SET

*

Refrig. Pressure

SET

SET

*

Oil Safety

SET

SET

*

Compressor overload

SET

SET

*

Freeze Stat

SET

SET

*

Low water level

SET

SET

*

Test Mode

*

Phase error

SET

SET

SET

*

NOTES:

*

The SPI I/O list defines the Processing bit as being cleared if the unit is not processing; otherwise it is SET.

Elsewhere on the chart:

If a bit is not shown to be SET, it is cleared.

The System Alarm bit is SET if an alarm is present. It is the logical OR of Process alarm and Machine alarm.

Processing, System Alarm, Process Alarm and Machine Alarm bits are repeated for Process Status, Machine 1

Status and Machine 2 Status.

SPI S

TATUS

W

ORDS

Open

Alarm,

Phase

Alarm,

Lo

w current

Alarm,

High current

Alarm,

Lo

w v

olts

Alarm,

High v

olts

Reser

ved

Reser

ved

Alarm,

Lo

w pressure saf

ety limit

Alarm,

High pressure saf

ety limit

Alarm,

Lo

w temperature saf

e

ty limit

Alarm,

High temperature saf

ety limit

Alarm,

Mac

hine

Alarm,

Pr

ocess

Alarm,

System

Pr

ocessing

Advertising
This manual is related to the following products: