Install the battery backup, Install the lights, Installation step 8 – Chamberlain 248754 User Manual

Page 18: Installation step 7

Advertising
background image

18

INSTALLATION STEP 8

Install the Lights

Press the release tabs on both sides of lens. Gently
rotate lens back and downward until the lens hinge is
in the fully open position. Do not remove the lens.

Install a 100 watt maximum light bulb in each socket.
Light bulb size should be A19, standard neck only. The
lights will turn ON and remain lit for approximately
4-1/2 minutes when power is connected. Then the
lights will turn OFF.

Reverse the procedure to close the lens.

Use A19, standard neck garage door opener bulbs for
replacement.

NOTE: Use only standard light bulbs. The use of short
neck or speciality light bulbs may overheat the endpanel
or light socket.

Lens
Hinge

100 Watt (Max)
Standard Light Bulb

Release Tab

100 Watt (Max)
Standard Light Bulb

INSTALLATION STEP 7

Install the Battery Backup

• Make sure motor unit is unplugged.

• Using a Phillips head screwdriver, remove the battery

cover on the motor unit.

• Partially insert battery into motor unit with terminals

facing out.

• Connect the red (+) and black (-) wires from motor

unit to corresponding terminals on battery.

• Replace battery cover.

To prevent possible OVERHEATING of the endpanel or light
socket:
• DO NOT use short neck or specialty light bulbs.
• DO NOT use halogen bulbs. Use ONLY incandescent.
To prevent damage to the opener:
• DO NOT use bulbs larger than 100W.
• ONLY use A19 size bulbs.

Battery

Battery Cover

ALWAYS wear protective gloves and eye protection when
changing the battery or working around the battery
compartment.

Advertising