MAINTENANCE

86037910 CEXT7 03/23/07

4-4

!

WARNING:

ONLY QUALIFIED
MAINTENANCE
PERSONNEL ARE

TO PERFORM THE FOLLOWING REPAIRS.

BELT REPLACEMENT

1. Turn off all switches and unplug machine.

2. Remove recovery tank and brush.

3. Remove the (2) screws that fasten the solution

tank to the frame, and tilt tank back to expose
the inside of the frame.

4. Loosen the (4) screws that hold the brush motor

in place and slide motor forward to release
tension in belt.

5. Remove the (2) screws that fasten the vacuum

shoe links (p/n 05016) to the brush housing.

6. Remove the (3) screws that fasten the side plate

(p/n 62759) to the brush housing to remove belt.
NOTE: All components associated with driving
the brush will come out with the side plate.

7. Reverse process to install belt.

86249420
PRV NO. 62759

86227350
PRV NO. 05016