MAINTENANCE

86037910 CEXT7 03/23/07

4-5

!

WARNING:

ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM
THE FOLLOWING REPAIRS.

SOLUTION PUMP REPLACEMENT

1. Turn off all switches and unplug the machine.

2. Remove recovery tank.

3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the

inside of the frame.

4. Remove solution hoses from fittings in pump.

5. Remove the (2) screws that fasten the pump to the frame.

6. Reverse process to install pump.

PUMP REPLACEMENT KITS SHURFLO 86026410 - PRV NO. (65257)

Valve Asm

86258840

PRV NO. 84162

Diaphragm

86235110

PRV NO. 29207

Pump Head

Replacement

86251050

PRV NO. 65188