Conversion to natural gas or lpg – CDA HCG 731 User Manual

Page 19

Advertising
background image

19

Conversion to Natural Gas or LPG

Replacing the Burner Injectors

If the NATURAL GAS/LPG conversion kit is not supplied with the appliance this kit can be purchased by
contacting the After-Sales Service.
Choose the injectors to be replaced according to the table below.
The injector diameter, expressed in hundredths of a millimetre, is marked on the injector body.

To replace the injectors proceed as follows:
– Remove the pan supports, the burner caps and flame speaders.
– Using a wrench, substitute the nozzle injectors “J” (Figs. 19 - 20) with those most suitable for the kind

of gas for which it is to be used.

The burners are made in such a way so as not to require regulation of the primary air.

J

J

Triple Ring
burner

Auxiliary,
Semi-Rapid
and Rapid
burners

Fig. 19

Fig. 20

Table for the Choice of the Injectors

Cat: II 2H 3+

Burners

Nominal

Power

kW

Reduced

Power

kW

G30 - 28-30 mbar

G31 - 37 mbar

G20 - 20 mbar

Ø Injector

1/100 mm

Ø Injector

1/100 mm

Auxiliary (A)

1,00

0,30

50

72 (X)

Semi-Rapid (SR)

1,75

0,45

65

97 (Z)

Rapid (R)

3,00

0,75

85

115 (Y)

Triple Ring (TR)

3,50

1,50

95

135 (T)