Dimmer Curve

To select the dimmer curve, do the following:

1) Go to MENU > INTRO > DIMMER.

2) Select DIMMER0~4.

DIMMER0: The output is proportional (linear) to the Dimmer and RGBW channel

values.

DIMMER1~4: The output follows the Dimmer and RGBW channel values based on the

corresponding dimmer curve, being DIM1 the fastest and DIM4 the
slowest.

Fader Reversal

This option allows you to define how the pan, tilt, and dimmer increase based on the
direction you move the corresponding fader.

1) Go to MENU > INVERT > PAN.

2) Select a fader direction (NORMAL or REVERSE).

3) Go to MENU > INVERT > TILT.

4) Select a fader direction (NORMAL or REVERSE).

5) Go to MENU > INVERT > DIMMER.

6) Select a fader direction (NORMAL or REVERSE).

7) Go to MENU > INVERT > USE.

8) Select YES to activate the new settings or NO to stop using them.

· When in NORMAL, the pan, tilt, and dimmer values will increase as the position

of the respective fader increases.

· When in REVERSE, the pan, tilt, and dimmer values will decrease as the position

of the respective fader increases.

Range Limitation

When it is necessary to limit the pan or tilt range, you can do the following:

1) Go to MENU > RANGE > P/START.

2) Select the starting point for the limited pan (000~255).

3) Go to MENU > RANGE > P/FINISH.

4) Select the finishing point for the limited pan (000~255).

5) Go to MENU > RANGE > T/START.

6) Select the starting point for the limited tilt (000~255).

7) Go to MENU > RANGE > T/FINISH.

8) Select the finishing point for the limited tilt (000~255).

9) Go to MENU > RANGE > USE.

10) Select YES to activate the new settings or NO to stop using them.

Reset Control

It is possible to select how you can reset the fixture, whether with the DMX controller or
only from the control panel.

1) Go to MENU > SPECIAL > RESET.

2) Select DMX or SYSTEM.

DMX: Enables the DMX controller to reset the fixture (Control function).

SYSTEM: Restricts the reset function to the control panel..