KPS-525 Power Supply

Installation Guide

Page 2 of 2

P/N: 01510-001 Rev. A

2.2

Power Requirements

24 VAC 50 VA Class 2 Transformer

2.3

Output

13.8 VDC @ 2.5 A (typical)

13.8 VDC @ .50 A (battery float charge)

14.2 VDC @ 2.0 A (DC output to NXT)

2.4

Operating Conditions

32°F to 150°F (0°C to 60°C) – 0% to 90% Relative Humidity, non-condensing

2.5

Cable Requirements

3.0

Contact Keri Systems

End of document.

Table 1: Cable Requirements

Connection

Total Run

Length

# of

Conductors

Shielded

Stranded

Twisted

-Pair

AWG

a

a. Heavier gauges then those listed are always acceptable.

Belden

Equivalent

AC power in

10 feet

2

N

Y

N

18

8442

ground

shortest

path

b

b. Use the shortest possible path from earth ground point to PCB. Connect the earth ground only to the

designated pin on the terminal block. This is important as all transient protection for the unit is made through
this earth ground connection. For unit protection, the earth ground connection should always be made first.

1

N

N

n/a

18

no specific

requirement

DC power out

10 feet

2

N

Y

N

18

8442

Keri USA

Keri UK, Ireland, Europe

2305 Bering Drive

San Jose, CA 95131

Unit 17

Park Farm Industrial Estate

Ermine Street

Buntingford

Herts SG9 9AZ UK

Telephone: (800) 260-5265

(408) 435-8400

Telephone: + 44 (0) 870 444 7234

Fax: (408) 435-7163

Fax:+ 44 (0) 1763 274 106

Web: www.kerisys.com

Web:www.kerisystems.co.uk

E-mail: [email protected]

[email protected]

E-mail:[email protected]
[email protected]

Advertising