0 enter-exit lane installation, V-track™ automatic long range vehicle id system, Exit enter – Keri Systems V-Track User Manual

Page 11

Advertising
background image

V-Track™ Automatic Long Range Vehicle ID System

Installation Guide

Page 11 of 20

P/N: 01538-001 Rev. G

6.0

Enter-Exit Lane Installation

The Keri RXR-10 receiver has the capability of controlling two EX-10 Exciters for Enter/Exit applications (see Figure
10).
The EX-10 Exciter should arrive configured for your application from the factor. Labels on the Exciter cover identify
individual units as either Single-Lane, Dual-Lane IN, or Dual-Lane OUT. Refer to Section 9.0 on page 20 should you
need to reconfigure an Exciter for a new purpose.

Figure 10: V-Track Enter-Exit Lane Application

RXR-10 Receiver

Gatehouse or similar location

EXIT

ENTER

EX-10 Exciter

EX-10 Exciter

RS-485 Connection

Shielded, Twisted Pair