Keri recommends the following cable gauges:

AWG 18 allows up to 500 feet

AWG 22 allows up to 200 feet

AWG 24 allows up to 100 feet

2.3

The Exciter’s Antenna

The EX-10 Exciter’s antenna can have a gain of no more than 8.1 db, per FCC regulations. For best operation the coaxial
cable between the antenna and transmitter should be kept as short as practical. We recommend no more than 10 feet.
Longer coax lengths than this will reduce the operating range of the system.

NOTE: The cable seals in the body of the Exciter enclosure are designed to accommodate one cable. Forcing more than
one cable through these seals compromises the weather-tight seal, allowing water to enter the body of the enclosure.

Table 1: EX-10 Exciter Electrical Requirements

Parameter

Requirement

Power Supply Nominal DC Voltage

12.0 VDC

Voltage Range

11.0 VDC to 15.0 VDC

Nominal Current

500 mA

Recommended Power Supply

12 VDC @ 1 A or greater
fully regulated

RF Connector Type

RPSMA