Serial Connection (RS232, RS485, or RS422 – Cont.)

Setting the DIP Switches (SW1, SW2, and SW3)
Note: Cycle BioPointe reader power after changing any DIP switch settings so
the reader will recognize the DIP switch change.

The BioPointe reader has three DIP switches:

SW1 – Sets the Device ID
SW2 – Sets the baud rate and communications type
SW3 – Sets the serial interface type (RS232, RS422, or RS485)

SW1: 8 mini-switches to set Device ID from 1 to 254 – refer to the BioPointe
Device ID Addressing Table. Device ID 0 is reserved for TCP/IP – LAN-50
devices. Device ID 255 is invalid.

SW2: 4 mini-switches, [1,2]

SW2: 4 mini-switches, [3,4]

Baud Rate

Communication Type

SW3: 8 mini-switches

Interface Type

S1

S2

S3

S4

S5

S6

S7

S8

RS232 *

-

-

-

ON

-

ON

-

ON

RS422

-

ON

ON

-

ON

-

ON

-

RS485

ON

-

ON

-

ON

-

ON

-

* Default Value

BioPointe

Pin

RS485

DB-9F Pin

3

-

-

4

-

-

5

-

-

6

D +

3

7

D -

2

8

-

-

RS485 Connections

BioPointe

Pin

RS422

DB-9F Pin

3

Rx +

2

4

Rx -

3

5

-

-

6

Tx +

4

7

Tx -

5

8

-

-

RS422 Connections

Baud Rate (Bps)

Switch 1

Switch 2

38400 *

ON

ON

19200

-

ON

9600

-

-

2400

ON

-

* Default Value

Comm Type

Switch 3

Switch 4

RS232 *

ON

ON

Modem

ON

-

TCP/IP

-

ON

RS422/485

-

-

* Default Value