Connecting to the adam rs485 converter, Adam wiring connections, Connecting to lan (ethernet – tcp/ip) – Keri Systems BioPointe Installation Guide User Manual

Page 5

Advertising
background image

Keri Systems, Inc.

5

01956-001 Rev. A

www.kerisys.com

Connecting to the ADAM RS485 Converter
The ADAM 4520 is an interface adapter, connected to the serial port of a PC
and converts data to RS485; you can then connect one or more BioPointe
devices to the ADAM. The ADAM requires 10-30 VDC, and is configured to
operate at 9600 baud. You can connect the ADAM to one, or more, BioPointe
readers.

ADAM Wiring Connections

Connecting to LAN (Ethernet – TCP/IP)
The BioPointe reader may be connected to a local area network (LAN) using a
Keri LAN-50 device. The LAN-50 should be assigned and addressed per the
instructions in the LAN-50/LAN-500 Application Note found on the Keri CD
or the Keri web site. Set the Baud rate of the LAN-50 to 38400; when the
BioPointe is set for TCP/IP its baud rate defaults to 38400. The IP address
assigned to the LAN-50, and port number 10001, must also be set in the
BioPointe Central software by going to Tools \ Device Management System \
Device Connection Setup. Set for Ethernet, port number 10001, and the
TCP/IP address of the LAN-50 to which the reader is connected, then save the
configuration. Each BioPointe requires a LAN-50 unit.