Maximum conditions at 25°c, Typical printing conditions, Aximum conditions at – KERN & SOHN VFS 2T1 Addendum User Manual

Page 9: 25°c, Ypical printing conditions, Advanced printing systems

Advertising
background image

EPM205

- Technical reference -

Rev. A

Page 9

Advanced Printing Systems

3.4. Maximum conditions at 25°C

Maximum conditions

Item

LV

HS

Unit

Supply energy

0.26

0.2

mJ/dot

Print cycle

2.5

1.25

ms/line

Supply voltage

7.2

8.5

V

Logic voltage

7

V

Head temperature

65

°C

Number of dots to be energized

simultaneously

1

192

dots

Notes:
· If energy applied to one dot, exceed the maximum value indicated on the above table, the print quality of

this dot may be definitively affected (usually makes a “light” print-out).

· If print cycle is less than 2.5 ms/line (above 50 mm/s) then maximum supply energy value is decreased.

For these applications, please contact A.P.S. for more information.

· When using double-ply paper or special low energy paper, please contact A.P.S. for more information.

3.5. Typical printing conditions

Electrical conditions

Item

Symbol

LV

HS

Unit

Supply voltage

VH

3.6

7.2

V

64 dots fired

Power consumption

Po

0.07

0.24

W/dot

at the same time

Print cycle

S.L.T.

2.5

1.25

ms/line

Eo

0.17

0.16

mJ/dot

Energy consumption

Ton

2.28

0.67

ms

5 °C

and ON Time at

Eo

0.15

0.13

mJ/dot

different working

Ton

2.01

0.54

ms

25 °C

temperatures

Eo

0.13

0.11

mJ/dot

Ton

1.74

0.46

ms

45 °C

Supply current

Io

1.6

2.4

A

The print optical density is then 1.0 minimum with a maximum variation of 0.3. This measurement is done
at the full black pattern by Macbeth densitometer RD-914. Full black pattern is defined as all dots printing
pattern (100% black area) printed under correct paper speed.


1

This condition satisfies the print density as defined in section 3.5

Advertising