8.1 Operation limits

• The weighing bridges are designed extremely robust. However the load limits

according to the following table should not be exceeded!

• Depending on the type of load receptacle, the static carrying capacity, i.e. the

maximum admissible load is:

Weighing

ranges

600kg

1500kg

With centrical load

3000kg 4500kg

With side stress

2000kg

3000kg

With one-sided loading

1000kg

1500kg

With single-wheel load

400kg

800kg

8.2 Operation with access ramps
• The load plate of the weighing bridge is an active weighing element, the access

ramps are passive, i.e. during the weighing process all wheels of the conveying
vehicles must rest on the load plate.

8.3 Load/unload weighing bridge
• Place the load on the scales using a lifting truck, a crane or a forklift truck. Ensure

that the load is not swinging when it is placed onto the scales.

• Lift the load first vertically at least 10 cm above the scales before it is removed or

newly placed.