10 preload, deadload and overload settings, Kern model, 300kg – KERN & SOHN KXP V20 User Manual

Page 18: 750kg, 1500kg

Advertising
background image

10 Preload, Deadload and Overload settings


Kern model

max. Preload* (kg)

* = additional initial load

Deadload** (kg)

**= already applied
preload

Center Overload
Protection circa
(kg)

Corner Overload
Protection circa
(kg)

Loadcell
Capacity (kg)

KXP 600V20SM

300kg

90

NA

N/A

500kg

KXP 600V20M

300kg

120

NA

N/A

500kg

KXP 1500V20SM

750kg

90

NA

N/A

1000kg

KXP 1500V20M

750kg

120

NA

N/A

1000kg

KXP 3000V20M

1500kg

120

NA

N/A

1500kg



Platform type

Platform dimension
(mm)

Loadcell

TC

Class

Max

E

max

E

min

Y

n

Dead-load

T

min

T

max

Cable-

Type

No.

Preload

-1

-4

-3

(kg)

-5

-6

length

(kg)

(kg)

(g)

(m)

KXP 600V20SM

1000x1000x80

CZL-8C-0.5T

D09-03.19

C3

300

500

0

10000

3000

300kg

-10

40

5

KXP 600V20M

1500x1250x80

CZL-8C-0.5T

D09-03.19

C3

300

500

0

10000

3000

300kg

-10

40

5

KXP 1500V20SM

1000x1000x80

CZL-8C-1T

D09-03.19

C3

750

1000

0

10000

3000

750kg

-10

40

5

KXP 1500V20M

1500x1250x80

CZL-8C-1T

D09-03.19

C3

750

1000

0

10000

3000

750kg

-10

40

5

KXP 3000V20M

1500x1250x80

CZL-8C-1.5T

D09-03.19

C3

1500

1500

0

10000

3000

1500kg

-10

40

5


18